@@ -0,0 +1,172 @@
|
||||
maintenance:
|
||||
|
||||
title: Med With Chem Restraint;;
|
||||
mlmname: FORM_MED_CHEM_RESTRAINT;;
|
||||
arden: version 2;;
|
||||
version: 4.50;;
|
||||
institution: St Clair;;
|
||||
author: Eclipsys Corp;;
|
||||
specialist: Mary Jo Goodwin ;;
|
||||
date: 2006-12-29;;
|
||||
validation: testing;;
|
||||
|
||||
library:
|
||||
purpose: Display appropriate fields depending on whether med
|
||||
if for Chemical Restraint or for a Medical Condition
|
||||
|
||||
;;
|
||||
|
||||
explanation: This MLM is called from the medication form once the user indicates
|
||||
if med is for {{{SINGLE-QUOTE}}}Chemical Retraint{{{SINGLE-QUOTE}}} or for a {{{SINGLE-QUOTE}}}Medical Condition{{{SINGLE-QUOTE}}}.
|
||||
|
||||
If drug is for a Chemical Restraint then the {{{SINGLE-QUOTE}}}Medical Condition{{{SINGLE-QUOTE}}} field is
|
||||
grayed out, the FrequencyCode field is hidden and a UDDI to enter the
|
||||
frequency (it is a subset of frequencies from the main list) is displayed.
|
||||
A second MLM will run when the frequency in the UDDI is selected and
|
||||
it will copy value to the hidden FrequencyCode field.
|
||||
|
||||
If drug is for a Medical Condition then field {{{SINGLE-QUOTE}}}Medical Condition{{{SINGLE-QUOTE}}} will become mandatory.
|
||||
|
||||
|
||||
Change history
|
||||
|
||||
04.12.2013 BB CSR# 26711 MLM - Update MLM to include new Orderset Form checkboxes for toggle gray out.
|
||||
08.09.2013 TMS Commented out lines that make prn reason box hidden and not mandatory. This is controlled
|
||||
through the FORM_PRN_REASON MLM to accommodate behavioral health mandatory reason for med
|
||||
orders. CSR 31639
|
||||
|
||||
|
||||
;;
|
||||
keywords: Called MLMs, Form fields, Chemical Restraint
|
||||
;;
|
||||
knowledge:
|
||||
type: data-driven;;
|
||||
data:
|
||||
|
||||
// This MLM is passed three arguments, of types
|
||||
// communication_type, form_type and client info object respectively.
|
||||
|
||||
(this_communication, // Communication object
|
||||
this_form, // Form object
|
||||
client_info_obj //Arden ClientInfo object
|
||||
) := argument;
|
||||
|
||||
|
||||
/*******************Make Changes To Spelling And Flags In This Section*******************/
|
||||
|
||||
|
||||
|
||||
|
||||
/***************************************************************************************/
|
||||
|
||||
// Initialize error message
|
||||
error_message:="";
|
||||
|
||||
triggerng_field := this_communication.CALLINGFIELDNAME;
|
||||
|
||||
// Assigns fields passed in the Form object to the Field object
|
||||
field_list:= this_form.fields;
|
||||
|
||||
// Added for Orderset Forms [BB]
|
||||
oschem_cb := last of (field_list where field_list.DataItemName = "NUR_Chemical Restraint" and field_List.Control_MultiFieldOccNum = 1);
|
||||
osmed_cb := last of (field_list where field_list.DataItemName = "NUR_Not Chemical Restraint" and field_List.Control_MultiFieldOccNum = 1);
|
||||
|
||||
chem_cb := last of (field_list where field_list.DataItemName = "NUR_Chemical Restraint" );
|
||||
med_cb := last of (field_list where field_list.DataItemName = "NUR_Not Chemical Restraint" );
|
||||
med_cond := last of (field_list where field_list.DataItemName = "NUR_Nonchemical Restraint Ind");
|
||||
restraint_freq := last of (field_list where field_list.DataItemName = "PRX_Chemical Restraint Freq");
|
||||
regular_freq := last of (field_list where field_list.DataItemName = "FrequencyCode");
|
||||
is_prn := last of (field_list where field_list.DataItemName = "IsPRN");
|
||||
is_prn_reason := last of (field_list where field_list.DataItemName = "PRX_PRNCondition");
|
||||
regular_freq_value := regular_freq.value;
|
||||
|
||||
if triggerng_field = "NUR_Chemical Restraint" and chem_cb.value = true then
|
||||
med_cb.value := FALSE;
|
||||
med_cb.control_read_only := TRUE;
|
||||
osmed_cb.value := FALSE;
|
||||
osmed_cb.control_read_only := TRUE;
|
||||
elseif triggerng_field = "NUR_Chemical Restraint" and chem_cb.value = false then
|
||||
med_cb.value := TRUE;
|
||||
med_cb.control_read_only := FALSE;
|
||||
chem_cb.control_read_only := TRUE;
|
||||
elseif triggerng_field = "NUR_Not Chemical Restraint" and med_cb.value = true then
|
||||
chem_cb.value := false;
|
||||
chem_cb.control_read_only := true;
|
||||
elseif triggerng_field = "NUR_Not Chemical Restraint" and med_cb.value = false then
|
||||
chem_cb.value := TRUE;
|
||||
chem_cb.control_read_only := false;
|
||||
med_cb.control_read_only := true;
|
||||
endif;
|
||||
|
||||
// Added to include the logic on the Orderset Form, as it has the same name and multi field occasion number [BB]
|
||||
if triggerng_field = "NUR_Chemical Restraint|1" and oschem_cb.value = true then
|
||||
osmed_cb.value := FALSE;
|
||||
osmed_cb.control_read_only := TRUE;
|
||||
elseif triggerng_field = "NUR_Chemical Restraint|1" and oschem_cb.value = false then
|
||||
osmed_cb.value := TRUE;
|
||||
osmed_cb.control_read_only := FALSE;
|
||||
oschem_cb.control_read_only := TRUE;
|
||||
elseif triggerng_field = "NUR_Not Chemical Restraint|1" and osmed_cb.value = true then
|
||||
oschem_cb.value := false;
|
||||
oschem_cb.control_read_only := true;
|
||||
elseif triggerng_field = "NUR_Not Chemical Restraint|1" and osmed_cb.value = false then
|
||||
oschem_cb.value := TRUE;
|
||||
oschem_cb.control_read_only := false;
|
||||
osmed_cb.control_read_only := true;
|
||||
endif;
|
||||
|
||||
|
||||
if chem_cb.Value = true then
|
||||
// if chemical restraint then hide the regular frequency field ,
|
||||
regular_freq.control_read_only := TRUE;
|
||||
regular_freq.control_mandatory := FALSE;
|
||||
regular_freq_value.FrequencySummary := NULL;
|
||||
// display the UDDI with the subset of frequencies
|
||||
restraint_freq.control_read_only := FALSE;
|
||||
restraint_freq.control_mandatory := TRUE;
|
||||
restraint_freq.value := NULL;
|
||||
// and make the medical condition field read only
|
||||
med_cond.value := "";
|
||||
med_cond.control_read_only := TRUE;
|
||||
med_cond.control_mandatory := FALSE;
|
||||
// and {{{SINGLE-QUOTE}}}IsPRN{{{SINGLE-QUOTE}}} is no longer an option
|
||||
is_prn.value := false;
|
||||
is_prn.control_read_only := TRUE;
|
||||
is_prn_reason.value := NULL;
|
||||
// is_prn_reason.control_mandatory := FALSE;
|
||||
// is_prn_reason.control_visible := FALSE;
|
||||
elseif med_cb.value = true then
|
||||
// if medical condition then make the regualr frequency field visible,
|
||||
regular_freq.control_read_only := FALSE;
|
||||
regular_freq.control_mandatory := TRUE;
|
||||
regular_freq_value.FrequencySummary := NULL;
|
||||
// hide the UDDI for the subset of frequencies
|
||||
restraint_freq.control_read_only := TRUE;
|
||||
restraint_freq.control_mandatory := FALSE;
|
||||
restraint_freq.value := NULL;
|
||||
// and make the medical condition field visible and mandatory
|
||||
med_cond.value := "";
|
||||
med_cond.control_read_only := FALSE;
|
||||
med_cond.control_mandatory := TRUE;
|
||||
// and {{{SINGLE-QUOTE}}}IsPRN{{{SINGLE-QUOTE}}} is an option
|
||||
is_prn.value := FALSE;
|
||||
is_prn.control_read_only := FALSE;
|
||||
is_prn_reason.value := NULL;
|
||||
// is_prn_reason.control_mandatory := FALSE;
|
||||
// is_prn_reason.control_visible := FALSE;
|
||||
endif;
|
||||
|
||||
|
||||
|
||||
;;
|
||||
evoke: // No evoke statement
|
||||
;;
|
||||
logic:
|
||||
|
||||
conclude true;
|
||||
;;
|
||||
action:
|
||||
// This MLM returns two parameters, of types communication_type and form_type respectively.
|
||||
return this_communication, this_form;
|
||||
;;
|
||||
end:
|
||||