Initial Checking with all 820 MLMs

This commit is contained in:
2020-02-02 00:54:01 -05:00
parent c59dc6de2e
commit 840d0432f4
828 changed files with 239162 additions and 0 deletions

View File

@@ -0,0 +1,137 @@
maintenance:
title: CCM Thoracentesis Orderset;;
mlmname: FORM_Set_CCM_Thoracentesis ;;
arden: version 2;;
version: 4.50;;
institution: St Clair;;
author: Robert Spence, Eclipsys Corp Ext 7461;;
specialist: ;;
date: 2009-09-22;;
validation: testing;;
library:
purpose: Used to select labs per left / right or both Thoracentesis
;;
explanation: This MLM is called from the CCM Thoracentesis Orderset
;;
keywords: Called MLMs,CCM Thoracentesis Orderset
;;
knowledge:
type: data-driven;;
data:
// This MLM is passed three arguments, of types
// communication_type, form_type and client info object respectively.
(this_communication, // Communication object
this_form, // Form object
client_info_obj //Arden ClientInfo object
) := argument;
/*******************Make Changes To Spelling And Flags In This Section*******************/
/* Set to true if a decision.log is needed.*/
log_execution_info := FALSE;
/***************************************************************************************/
// Initialize error message
error_message:="";
// Assigns fields passed in the Form object to the Field object
field_list:= this_form.fields;
CallingEvent := this_communication.CallingEvent;
CallingField := this_communication.CallingFieldName;
fldleft := last of (field_list where field_list.DataItemName = "CCM Left Thoracentesis");
fldright := last of (field_list where field_list.DataItemName = "CCM Right Thoracentesis");
fldleftright := last of (field_list where field_list.DataItemName = "CCM L/R Thoracentesis");
listcbs:= ();
allvalue := false;
if Callingfield = "CCM Left Thoracentesis|1" then
allvalue := fldleft.Value;
listcbs:=(2);
if fldleft.Value = True then
fldright.control_read_only := True;
fldleftright.control_read_only := True;
else
fldright.control_read_only := False;
fldleftright.control_read_only := False;
endif;
elseif Callingfield = "CCM Right Thoracentesis|1" then
allvalue := fldright.Value;
listcbs:=(3);
if fldright.Value = True then
fldleft.control_read_only := True;
fldleftright.control_read_only := True;
// set grid here, name of grid to change or list and to change to.
else
fldleft.control_read_only := False;
fldleftright.control_read_only := False;
// set grid here, name of grid to change or list and to change to.
endif;
elseif Callingfield = "CCM L/R Thoracentesis|1" then
allvalue := fldleftright.Value;
listcbs:=(2,3);
if fldleftright.Value = True then
fldleft.control_read_only := True;
fldright.control_read_only := True;
// set grid here, name of grid to change or list and to change to.
else
fldleft.control_read_only := False;
fldright.control_read_only := False;
// set grid here, name of grid to change or list and to change to.
endif;
endif;
listcbsproc:= count listcbs;
for k in (1 seqto listcbsproc) do
gridwork := listcbs[k];
Grid_fld := last of (field_list where field_list.DataItemName = "MultiOrderCheckBox"
and field_List.Control_MultiFieldOccNum = gridwork);
Grid_list :=Grid_fld.Value;
Grid_SelList := Grid_List.IsSelected;
ListMembs:= count Grid_SelList;
setlist := ();
for j in (1 seqto ListMembs) do
setlist := setlist, allvalue;
enddo;
Grid_List.IsSelected:= setlist;
enddo;
;;
evoke: // No evoke statement
;;
logic:
conclude true;
;;
action:
// This MLM returns two parameters, of types communication_type and form_type respectively.
return this_communication, this_form;
;;
end: