Initial Checking with all 820 MLMs

This commit is contained in:
2020-02-02 00:54:01 -05:00
parent c59dc6de2e
commit 840d0432f4
828 changed files with 239162 additions and 0 deletions

View File

@@ -0,0 +1,327 @@
maintenance:
title: FORM_SET_HEMORRHAGIC_STROKE_OS;;
mlmname: FORM_SET_HEMORRHAGIC_STROKE_OS;;
arden: version 2.5;;
version: 15.10;;
institution: St Clair Hospital;;
author: Shivprasad Jadhav, Allscripts ;;
specialist: Dr. Janardhan Chavan, Allscripts;;
date: 2016-05-09;;
validation: testing;;
library:
purpose: When user selects any UDDI or gets checked from user, then respective item should get selected from below grid,
and there are some orders which should be grayed out for this details please refer to Details Tab and Screen Shot tab
;;
explanation: This MLM is called from Hemorrhagic Stroke Order Set
Change history
------------------------------------------------------------------------------------
06.01.2017 SSJ CSR 35323: Created for Hemorrhagic Stroke Order Set
06.21.2018 TMS CSR 36420: Add copy of Hemorrhagic Stroke Order Set to allow prechecking of
Warfarin Reversal or NOAC Reversal to enable correct logic on called order
set depending upon option selected on Parent Order Set.
;;
keywords: Called MLMs, Hemorrhagic Stroke
;;
knowledge:
type: data-driven;;
data:
standard_libs := mlm {{{SINGLE-QUOTE}}}std_include_libs{{{SINGLE-QUOTE}}};
include standard_libs;
using "ObjectsPlusXA.SCM.Forms";
using namespace "ObjectsPlusXA.SunriseClinicalManager.Forms";
// This MLM is passed three arguments, of types
// communication_type, form_type and client info object respectively.
(this_communication, // Communication object
this_form, // Form object
client_info_obj //Arden ClientInfo object
) := argument;
ClientGuid := this_communication.ClientGUID;
ChartGuid := this_communication.ChartGUID;
ClientVisitGuid := this_communication.ClientVisitGUID;
PrimaryObjdetail:=this_communication.PrimaryObj;
OrderSetName := PrimaryObjdetail.OrderSetName;
/*******************Make Changes To Spelling And Flags In This Section*******************/
/* Set to True if a decision.log is needed.*/
log_execution_info := False;
/***************************************************************************************/
// Initialize error message
error_message:="";
BaseMLM := MLM {{{SINGLE-QUOTE}}}FORM_MEDICAL_IMAGING_INDICATIONS_FOR_OS{{{SINGLE-QUOTE}}} ;
enable_chkbx_mlm := mlm {{{SINGLE-QUOTE}}}FORM_Func_Disable_OS_Checkboxes{{{SINGLE-QUOTE}}};
exceptFld := ();
FFPSel := 0 ;
// Assigns fields passed in the Form object to the Field object
field_list:= this_form.fields;
CallingEvent := this_communication.CallingEvent;
CallingField := this_communication.CallingFieldName;
//Define fields
Chk_Phyto := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 1 );
Chk_KCentra1 := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 2 );
Chk_FFP1 := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 3 );
Chk_KCentra2 := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 4 );
Chk_FFP2 := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 5 );
Chk_Idaruci := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 6 );
Chk_FFP3 := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 7 );
Chk_Prota := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 8 );
Chk_FFP4 := first of ( field_list WHERE field_list.DataItemName = "PRX_Checkbox1" AND field_list.Control_MultiFieldOccNum = 9 );
Order_Grid := first of ( field_list WHERE field_list.DataItemName = "MultiOrderGrid" AND field_list.Control_MultiFieldOccNum = 62 );
Order2_Grid := first of ( field_list WHERE field_list.DataItemName = "MultiOrderGrid" AND field_list.Control_MultiFieldOccNum = 68 );
FFP_Grid := first of ( field_list WHERE field_list.DataItemName = "MultiOrderGrid" AND field_list.Control_MultiFieldOccNum = 69 );
Order_Grid_Value := Order_Grid.Value;
Order2_Grid_Value := Order2_Grid.Value;
FFP_Grid_Value := FFP_Grid.Value;
G_Phyto := first of ( Order_Grid_Value WHERE Order_Grid_Value.Name = "Phytonadione:" );
G_Prota := first of ( Order_Grid_Value WHERE Order_Grid_Value.Name Matches Pattern "Protamine%" );
G_Prothro := Order2_Grid_Value[1] ; //Name = "Prothrombin Complex Concentrate for Emergent Warfarin Reversal" For Warfarin Reversal
G_Prothro2 := Order2_Grid_Value[2] ; //Name = "Prothrombin Complex Concentrate for Emergent Warfarin Reversal" For NOAC Reversal
G_Idaruci := Order2_Grid_Value[3] ; //Name = "Idarucizumab 5gm"
G_FFP := FFP_Grid_Value[1] ; // Name = "FFP Orders"
if ( CallingEvent = "FormOpen" ) then
//To Call Base MLM
(this_communication, this_form) := call BaseMLM WITH this_communication, this_form, client_info_obj;
for item IN Order_Grid_Value do
item.IsReadonly := true;
enddo;
for item IN Order2_Grid_Value do
item.IsReadonly := true;
enddo;
for item IN FFP_Grid_Value do
item.IsReadonly := False;
enddo;
endif;
if ( CallingEvent = "FieldChange" ) then
//********** Phytonadione ********************
if ( CallingField = "PRX_Checkbox1|1" ) then
fieldValue := Chk_Phyto.Value;
exceptFld := exceptFld, CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
Chk_FFP4.DataItemName || "|" || Chk_FFP4.Control_MultiFieldOccNum ;
If Chk_FFP1.Value = True Then exceptFld := exceptFld,Chk_FFP1.DataItemName || "|" || Chk_FFP1.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP2.Value = True Then exceptFld := exceptFld,Chk_FFP2.DataItemName || "|" || Chk_FFP2.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP3.Value = True Then exceptFld := exceptFld,Chk_FFP3.DataItemName || "|" || Chk_FFP3.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If FFPSel = 0 Then exceptFld := exceptFld,Chk_FFP1.DataItemName || "|" || Chk_FFP1.Control_MultiFieldOccNum; EndIf;
if ( fieldValue = true ) then
G_Phyto.IsSelected := true ;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
G_Phyto.IsSelected := False;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld;
endif;
endif;
//************** KCentra Order **************
if ( CallingField = "PRX_Checkbox1|2" ) then
fieldValue := CHK_KCentra1.Value;
exceptFld := exceptFld, CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
Chk_FFP4.DataItemName || "|" || Chk_FFP4.Control_MultiFieldOccNum ;
If Chk_FFP1.Value = True Then exceptFld := exceptFld,Chk_FFP1.DataItemName || "|" || Chk_FFP1.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP2.Value = True Then exceptFld := exceptFld,Chk_FFP2.DataItemName || "|" || Chk_FFP2.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP3.Value = True Then exceptFld := exceptFld,Chk_FFP3.DataItemName || "|" || Chk_FFP3.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If FFPSel = 0 Then exceptFld := exceptFld,Chk_FFP1.DataItemName || "|" || Chk_FFP1.Control_MultiFieldOccNum; EndIf;
if ( fieldValue = true ) then
G_Prothro.IsSelected := True;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
G_Prothro.IsSelected := False;
if ( CHK_KCentra2.Value = false ) then
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld;
endif;
endif;
endif;
if ( CallingField = "PRX_Checkbox1|4" ) then
fieldValue := CHK_KCentra2.Value;
exceptFld := exceptFld, CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
Chk_FFP4.DataItemName || "|" || Chk_FFP4.Control_MultiFieldOccNum ;
If Chk_FFP1.Value = True Then exceptFld := exceptFld,Chk_FFP1.DataItemName || "|" || Chk_FFP1.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP2.Value = True Then exceptFld := exceptFld,Chk_FFP2.DataItemName || "|" || Chk_FFP2.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP3.Value = True Then exceptFld := exceptFld,Chk_FFP3.DataItemName || "|" || Chk_FFP3.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If FFPSel = 0 Then exceptFld := exceptFld,Chk_FFP2.DataItemName || "|" || Chk_FFP2.Control_MultiFieldOccNum; EndIf;
if ( fieldValue = true ) then
G_Prothro2.IsSelected := True;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
G_Prothro2.IsSelected := False;
if ( CHK_KCentra1.Value = false ) then
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld;
endif;
endif;
endif;
//************** Idarucizumab 2.5 Grams ********************
if ( CallingField = "PRX_Checkbox1|6" ) then
fieldValue := Chk_Idaruci.Value;
exceptFld := exceptFld, CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
Chk_FFP4.DataItemName || "|" || Chk_FFP4.Control_MultiFieldOccNum;
If Chk_FFP1.Value = True Then exceptFld := exceptFld,Chk_FFP1.DataItemName || "|" || Chk_FFP1.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP2.Value = True Then exceptFld := exceptFld,Chk_FFP2.DataItemName || "|" || Chk_FFP2.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If Chk_FFP3.Value = True Then exceptFld := exceptFld,Chk_FFP3.DataItemName || "|" || Chk_FFP3.Control_MultiFieldOccNum; FFPSel :=1 ; EndIf;
If FFPSel = 0 Then exceptFld := exceptFld,Chk_FFP3.DataItemName || "|" || Chk_FFP3.Control_MultiFieldOccNum; EndIf;
if ( fieldValue = true ) then
G_Idaruci.IsSelected := true;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
G_Idaruci.IsSelected := false;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld;
endif;
endif;
//************** Fresh Frozen Plasma ********************
if ( CallingField = "PRX_Checkbox1|3" ) then
fieldValue := Chk_FFP1.Value;
exceptFld := exceptFld, CHK_Phyto.DataItemName || "|" || CHK_Phyto.Control_MultiFieldOccNum,
CHK_KCentra1.DataItemName || "|" || CHK_KCentra1.Control_MultiFieldOccNum,
CHK_KCentra2.DataItemName || "|" || CHK_KCentra2.Control_MultiFieldOccNum,
CHK_Idaruci.DataItemName || "|" || CHK_Idaruci.Control_MultiFieldOccNum,
CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
CHK_FFP4.DataItemName || "|" || CHK_FFP4.Control_MultiFieldOccNum ;
if ( fieldValue = true ) then
G_FFP.IsSelected := true;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
if ( Chk_FFP2.Value = false And Chk_FFP3.Value = false and Chk_FFP4.Value = false ) then
G_FFP.IsSelected := False;
endif;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld ;
endif;
endif;
if ( CallingField = "PRX_Checkbox1|5" ) then
fieldValue := Chk_FFP2.Value;
exceptFld := exceptFld, CHK_Phyto.DataItemName || "|" || CHK_Phyto.Control_MultiFieldOccNum,
CHK_KCentra1.DataItemName || "|" || CHK_KCentra1.Control_MultiFieldOccNum,
CHK_KCentra2.DataItemName || "|" || CHK_KCentra2.Control_MultiFieldOccNum,
CHK_Idaruci.DataItemName || "|" || CHK_Idaruci.Control_MultiFieldOccNum,
CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
CHK_FFP4.DataItemName || "|" || CHK_FFP4.Control_MultiFieldOccNum ;
if ( fieldValue = true ) then
G_FFP.IsSelected := true;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
if ( Chk_FFP1.Value = false And Chk_FFP3.Value = false and Chk_FFP4.Value = false ) then
G_FFP.IsSelected := False;
endif;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld ;
endif;
endif;
if ( CallingField = "PRX_Checkbox1|7" ) then
fieldValue := Chk_FFP3.Value;
exceptFld := exceptFld, CHK_Phyto.DataItemName || "|" || CHK_Phyto.Control_MultiFieldOccNum,
CHK_KCentra1.DataItemName || "|" || CHK_KCentra1.Control_MultiFieldOccNum,
CHK_KCentra2.DataItemName || "|" || CHK_KCentra2.Control_MultiFieldOccNum,
CHK_Idaruci.DataItemName || "|" || CHK_Idaruci.Control_MultiFieldOccNum,
CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
CHK_FFP4.DataItemName || "|" || CHK_FFP4.Control_MultiFieldOccNum ;
if ( fieldValue = true ) then
G_FFP.IsSelected := true;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
if ( Chk_FFP1.Value = false And Chk_FFP2.Value = false and Chk_FFP4.Value = false ) then
G_FFP.IsSelected := False;
endif;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld;
endif;
endif;
if ( CallingField = "PRX_Checkbox1|9" ) then
fieldValue := Chk_FFP4.Value;
exceptFld := exceptFld, CHK_Phyto.DataItemName || "|" || CHK_Phyto.Control_MultiFieldOccNum,
CHK_KCentra1.DataItemName || "|" || CHK_KCentra1.Control_MultiFieldOccNum,
CHK_KCentra2.DataItemName || "|" || CHK_KCentra2.Control_MultiFieldOccNum,
CHK_Idaruci.DataItemName || "|" || CHK_Idaruci.Control_MultiFieldOccNum,
CHK_Prota.DataItemName || "|" || CHK_Prota.Control_MultiFieldOccNum,
CHK_FFP4.DataItemName || "|" || CHK_FFP4.Control_MultiFieldOccNum ;
If Chk_FFP1.Value = True Then exceptFld := exceptFld,Chk_FFP1.DataItemName || "|" || Chk_FFP1.Control_MultiFieldOccNum; EndIf;
If Chk_FFP2.Value = True Then exceptFld := exceptFld,Chk_FFP2.DataItemName || "|" || Chk_FFP2.Control_MultiFieldOccNum; EndIf;
If Chk_FFP3.Value = True Then exceptFld := exceptFld,Chk_FFP3.DataItemName || "|" || Chk_FFP3.Control_MultiFieldOccNum; EndIf;
if ( fieldValue = true ) then
G_FFP.IsSelected := true;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
if ( Chk_FFP1.Value = false And Chk_FFP2.Value = false and Chk_FFP3.Value = false ) then
G_FFP.IsSelected := False;
endif;
rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld;
endif;
endif;
//********** Protamine ********************
if ( CallingField = "PRX_Checkbox1|8" ) then
fieldValue := Chk_Prota.Value;
if ( fieldValue = true ) then
G_Prota.IsSelected := true ;
//rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, true, exceptFld;
elseif ( fieldValue = false ) then
G_Prota.IsSelected := False;
//rtnValue := call enable_chkbx_mlm WITH this_communication, this_form, client_info_obj, CallingField, false, exceptFld;
endif;
endif;
endif; //End FieldChange
;;
evoke: // No evoke statement
;;
logic:
conclude True;
;;
action:
// This MLM returns two parameters, of types communication_type and form_type respectively.
return this_communication, this_form;
;;
end: