maintenance:
title: Ordering: PCA ordering ;;
mlmname: FORM_Rx_PCA_Field_Edits;;
arden: version 2;;
version: 4.50;;
institution: St Clair Isolation Set MLM;;
author: Don Warnick, Eclipsys Corp;;
specialist: ;;
date: 2006-04-06;;
validation: testing;;
library:
purpose: Change the status of fields based upon the infusion selected
;;
explanation: This MLM is called from the PRX_ljPCA form. It ensures that the correct fields are populated and the correct
frequency is attached to PCA orders based upon the method of delivery.
change history
12.13.2007 DJW Added additional code for new "No Lockout" and "Standard Lockout" check boxes.
02.15.2013 TMS Added logic to allow a "No Lockout" or "Other Lockout" to the hydromorphone 6mg/30ml concentration
when ordered by or on behalf of Dr. Rivero for pain management orders. If Dr. Rivero is not the
ordering care provider the user cannot see the checkboxes for no lockout or other lockout. CSR 31172
12.03.2015 GOS CSR :33435 & 33436 - on selection other PCA Alone, Cont Insulation, Cont Infusion we display, Hide and Make Madatory PCA reason 1 and PCA Reason 2
11.14.2018 TMS CSR 37423 Add logic to auto select Standard Lockout when switching between continuous and patient controlled. Physician no longer at St. Clair
leaving logic in case new pain med doctors ever want to choose between other and no lockout.
;;
keywords: Called MLMs, Form fields, PCA
;;
knowledge:
type: data-driven;;
data:
// This MLM is passed three arguments, of types
// communication_type, form_type and client info object respectively.
(this_communication, // Communication object
this_form, // Form object
client_info_obj //Arden ClientInfo object
) := argument;
/*******************Make Changes To Spelling And Flags In This Section*******************/
/* Set to true if a decision.log is needed.*/
log_execution_info := FALSE;
/***************************************************************************************/
comm_obj := this_communication.primaryobj;
// Initialize error message
error_message:="";
// Assigns fields passed in the Form object to the Field object
field_list:= this_form.fields;
CallingEvent := this_communication.CallingEvent;
CallingField := this_communication.CallingFieldName;
OrderingPhysician := this_communication.CareProviderDisplayName;
pca := last of (field_list where field_list.DataItemName = "PRX_Pca" );
pcacontinuous:= last of (field_list where field_list.DataItemName = "PRX_PcaContinuous" );
pcaplus := last of (field_list where field_list.DataItemName = "PRX_PcaPlus" );
stdlockout := last of (field_list where field_list.DataItemName = "PRX_SP08" );
nolockout := last of (field_list where field_list.DataItemName = "PRX_SP09" );
otherlockout := last of (field_list where field_list.DataItemName = "PRX_SP10" );
stdlockoutval:= last of (field_list where field_list.DataItemName = "PRX_PcaLockoutStdValue" );
rnadmdose := last of (field_list where field_list.DataItemName = "PRX_ZXO01" );
rnadmunits := last of (field_list where field_list.DataItemName = "PRX_ZXO02" );
maxdose := last of (field_list where field_list.DataItemName = "PRX_ZXO03" );
unitsmg2 := last of (field_list where field_list.DataItemName = "PRX_ZXO04" );
patadmindose := last of (field_list where field_list.DataItemName = "PRX_ZXO05" );
unitsmg1 := last of (field_list where field_list.DataItemName = "PRX_ZXO06" );
everyfreq := last of (field_list where field_list.DataItemName = "PRX_ZXO07" );
unitsminutes := last of (field_list where field_list.DataItemName = "PRX_ZXO08" );
continrate := last of (field_list where field_list.DataItemName = "PRX_ZXO09" );
unitsmghr := last of (field_list where field_list.DataItemName = "PRX_ZXO10" );
bolusprn := last of (field_list where field_list.DataItemName = "PRX_ZXO11" );
bolusprnunits:= last of (field_list where field_list.DataItemName = "PRX_ZXO12" );
bolusint := last of (field_list where field_list.DataItemName = "PRX_ZXO15" );
bolusintunits:= last of (field_list where field_list.DataItemName = "PRX_ZXO16" );
frequency := last of (field_list where field_list.DataItemName = "FrequencyCode" );
freq_Val := frequency.Value;
prn := last of (field_list where field_list.DataItemName = "IsPRN" );
perminfo := last of (field_list where field_list.DataItemName = "PRX_PermOrderInfo" );
tempinfo := last of (field_list where field_list.DataItemName = "PRX_TempOrderInfo" );
// Added By Shivprasad
PCA_Reason1 := last of ( field_list WHERE field_list.DataItemName = "PRX_PCA Reason1" );
PCA_Reason2 := last of ( field_list WHERE field_list.DataItemName = "PRX_PCA Reason2" );
PCA_Condition := last of ( field_list WHERE field_list.DataItemName = "PRX_PRNCONDITION" ) ;
If CallingEvent = "FormOpen" and (this_communication.CareProviderDisplayName = "Spicuzza, Teresa" or
this_communication.CareProviderDisplayName = "Rivero-Becerra, Jorge R") then
painmgtorder := true;
nolockout.control_read_only := False;
nolockout.control_visible := True;
otherlockout.control_read_only := False;
otherlockout.control_visible := True;
else
painmgtorder := false;
endif;
If CallingEvent = "FormOpen" and (this_communication.CareProviderDisplayName = "Spicuzzatest, Teresa" or
this_communication.CareProviderDisplayName = "Rivero-Becerra, Jorge R") then
painmgtorder := true;
nolockout.control_read_only := False;
nolockout.control_visible := True;
otherlockout.control_read_only := False;
otherlockout.control_visible := True;
else
painmgtorder := false;
endif;
// Start : Added By Shivprasad Jadhav for CSR #
If comm_obj.Name ="Hydromorphone PCA (30mg/30ml)" Then
pcaconcentrated := "True" ;
Elseif comm_obj.Name ="Hydromorphone PCA (6mg/30ml)" Then
pcaconcentrated := "False" ;
stdlockout.Value := true ;
Elseif comm_obj.Name ="Morphine PCA" Then
pcaconcentrated := "False" ;
Endif;
If CallingEvent="FormClose"
then
tempinfo.value := "";
If (pca.value = False) and
(pcacontinuous.value = False) and
(pcaplus .value = False)
then
this_communication.DisplayForm := "Yes";
this_communication.Message := "No PCA mode of delivery was selected" || "\n" || "\n" || "Please check at least one of the boxes";
this_communication.MessageType := "Error";
elseif (stdlockout.value = False) and
(nolockout.value = False) and
(otherlockout .value = False) and
(pcacontinuous.value = False)
then
this_communication.DisplayForm := "Yes";
this_communication.Message := "No lockout value was selected" || "\n" || "\n" || "Please check at least one of the boxes";
this_communication.MessageType := "Error";
endif;
endif;
If (CallingField = "Prx_PCA" and pca.value = True) or (CallingEvent = "FormOpen" and pca.value = True)
then
pcacontinuous.value := False;
pcaplus.value := False;
patadmindose.control_mandatory := True;
patadmindose.control_read_only := False;
unitsmg1.value := "mg";
unitsmg1.control_mandatory := True;
unitsmg1.control_read_only := True;
everyfreq.control_mandatory := True;
everyfreq.control_read_only := False;
unitsminutes.value := "minutes";
unitsminutes.control_mandatory := True;
unitsminutes.control_read_only := True;
freq_Val.FrequencySummary := "As Ordered";
frequency.Value := freq_Val;
prn.value := True;
prn.control_read_only := True;
continrate.value := "";
continrate.control_mandatory := False;
continrate.control_read_only := True;
unitsmghr.value := "";
unitsmghr.control_mandatory := False;
unitsmghr.control_read_only := True;
nolockout.control_read_only := False;
stdlockout.control_read_only := False;
otherlockout.control_read_only := False;
If pcaconcentrated = "True" Then
PCA_Reason1.Control_Visible := False ;
PCA_Reason2.Control_Visible := True ;
PCA_Reason2.Control_Read_Only:=False ;
PCA_Reason2.Control_Mandatory := True ;
Elseif pcaconcentrated = "False" Then
PCA_Reason1.Control_Visible := True ;
PCA_Reason2.Control_Visible := False ;
PCA_Reason1.Control_Read_Only:= True ;
PCA_Reason1.Control_Mandatory := False ;
Endif;
If stdlockout.Value = true then
maxdose.value := stdlockoutval.value;
unitsmg2.value := "mg";
endif;
elseif (CallingField = "Prx_PcaPlus" and pcaplus.value = True) or (CallingEvent = "FormOpen" and pcaplus.value = True)
then
pca.value := False;
pcacontinuous.value := False;
patadmindose.control_mandatory := True;
patadmindose.control_read_only := False;
unitsmg1.value := "mg";
unitsmg1.control_mandatory := True;
unitsmg1.control_read_only := True;
everyfreq.control_mandatory := True;
everyfreq.control_read_only := False;
unitsminutes.value := "minutes";
unitsminutes.control_mandatory := True;
unitsminutes.control_read_only := True;
freq_Val.FrequencySummary := "<Continuous>";
frequency.Value := freq_Val;
prn.value := False;
prn.control_read_only := True;
continrate.control_mandatory := True;
continrate.control_read_only := False;
unitsmghr.value := "mg/hr";
nolockout.control_read_only := False;
stdlockout.control_read_only := False;
otherlockout.control_read_only := False;
If pcaconcentrated = "True" Then
PCA_Reason1.Control_Visible := False ;
PCA_Reason2.Control_Visible := True ;
PCA_Reason2.Control_Read_Only:=False ;
PCA_Reason2.Control_Mandatory := True ;
Elseif pcaconcentrated = "False" Then
PCA_Reason1.Control_Visible := True ;
PCA_Reason2.Control_Visible := False ;
PCA_Reason1.Control_Read_Only:= False ;
PCA_Reason1.Control_Mandatory := True ;
Endif;
If stdlockout.value = true then
maxdose.value := stdlockoutval.value;
unitsmg2.value := "mg";
endif;
elseif (CallingField = "PRX_PcaContinuous" and pcacontinuous.value = True) or (CallingEvent = "FormOpen" and pcacontinuous.value = True)
then
pca.value := False;
pcaplus.value := False;
patadmindose.value := "";
patadmindose.control_mandatory := False;
patadmindose.control_read_only := True;
unitsmg1.value := "";
unitsmg1.control_mandatory := False;
unitsmg1.control_read_only := True;
everyfreq.value := "";
everyfreq.control_mandatory := False;
everyfreq.control_read_only := True;
unitsminutes.value := "";
unitsminutes.control_mandatory := False;
unitsminutes.control_read_only := True;
maxdose.value := "";
maxdose.control_mandatory := False;
maxdose.control_read_only := True;
unitsmg2.value := "";
unitsmg2.control_mandatory := False;
unitsmg2.control_read_only := True;
freq_Val.FrequencySummary := "<Continuous>";
frequency.Value := freq_Val;
prn.value := False;
prn.control_read_only := True;
continrate.control_mandatory := True;
continrate.control_read_only := False;
unitsmghr.value := "mg/hr";
nolockout.value := False;
nolockout.control_read_only := True;
stdlockout.value := False;
stdlockout.control_read_only := True;
otherlockout.value := False;
otherlockout.control_read_only := True;
If pcaconcentrated = "True" Then
PCA_Reason1.Control_Visible := False ;
PCA_Reason2.Control_Visible := True ;
PCA_Reason2.Control_Read_Only:=False ;
PCA_Reason2.Control_Mandatory := True ;
Elseif pcaconcentrated = "False" Then
PCA_Reason1.Control_Visible := True ;
PCA_Reason2.Control_Visible := False ;
PCA_Reason1.Control_Read_Only:= False ;
PCA_Reason1.Control_Mandatory := True ;
Endif;
endif;
If (CallingField = "PRX_SP08" and stdlockout.value = True) or (CallingEvent = "FormOpen" and stdlockout.value = True)
then
maxdose.control_mandatory := False;
maxdose.control_read_only := True;
maxdose.value := stdlockoutval.value;
unitsmg2.value := "mg";
unitsmg2.control_mandatory := True;
unitsmg2.control_read_only := True;
nolockout.value := False;
otherlockout.value := False;
elseif (CallingField = "PRX_SP09" and nolockout.value = True) or (CallingEvent = "FormOpen" and nolockout.value = True)
then
maxdose.control_mandatory := False;
maxdose.control_read_only := True;
maxdose.value := " ";
unitsmg2.value := " ";
unitsmg2.control_mandatory := False;
unitsmg2.control_read_only := True;
stdlockout.value := False;
otherlockout.value := False;
elseif (CallingField = "PRX_SP10" and otherlockout.value = True) or (CallingEvent = "FormOpen" and otherlockout.value = True)
then
maxdose.control_mandatory := True;
maxdose.control_read_only := False;
maxdose.value := " ";
unitsmg2.value := "mg";
unitsmg2.control_mandatory := False;
unitsmg2.control_read_only := True;
stdlockout.value := False;
nolockout.value := False;
endif;
If CallingField = "PRX_ZXO01" then
If rnadmdose.value <> " " then rnadmunits.value := "mg";
elseif rnadmdose.value is null then rnadmunits.value := " ";
endif;
endif;
If CallingField = "PRX_ZXO11" then
If bolusprn.value <> " " then bolusprnunits.value := "mg";
elseif bolusprn.value is null then bolusprnunits.value := " ";
endif;
endif;
If CallingField = "PRX_ZXO15" then
If bolusint.value <> " " then bolusintunits.value := "hours";
elseif bolusint.value is null then bolusintunits.value := " ";
endif;
endif;
// Added By Shivprasad Jadhav
If (CallingField = "PRX_PCA Reason1" and PCA_Reason1.Value Is Not Null ) or (CallingEvent = "FormOpen" And PCA_Reason1.Value Is Not Null )
or (CallingField = "PRX_PCA Reason2" and PCA_Reason2.Value Is Not Null ) or (CallingEvent = "FormOpen" And PCA_Reason2.Value Is Not Null )
Then
If PCA_Reason1.Value Is Not Null Then
If PCA_Reason1.Value ="Recommended by Pain Management Consultant" Then
SelectionVal1 := "Pain Mgt Consult" ;
Elseif PCA_Reason1.Value ="End of Life" Then
SelectionVal1 := "End of Life" ;
Elseif PCA_Reason1.Value ="Inadequate Pain Response to IV Narcotics over a 24 hour period" Then
SelectionVal1 := "Inadequate pain response over 24hrs" ;
Elseif PCA_Reason1.Value ="Chronic narcotic use prior to admission" Then
SelectionVal1 := "Chronic narcotic use" ;
Else
SelectionVal1 := "" ;
Endif;
ElseIf PCA_Reason2.Value Is Not Null Then
If PCA_Reason2.Value ="Recommended by Pain Management Consultant" Then
SelectionVal1 := "Pain Mgt Consult" ;
Elseif PCA_Reason2.Value ="End of Life" Then
SelectionVal1 := "End of Life" ;
Elseif PCA_Reason2.Value ="Oncology patient receiving escalating doses of IV hydromorphone with inadequate pain relief" Then
SelectionVal1 := "Onc. Pt with inadequate pain relief" ;
Else
SelectionVal1 := "" ;
Endif;
Elseif ((PCA_Reason1.Value = Null) And (PCA_Reason2.Value = Null) ) Then
SelectionVal1 := "" ;
Endif;
PCA_Condition.Value := SelectionVal1 ;
PCA_Condition.Control_Visible := True;
Endif;
/* this_communication.DisplayForm := "Yes";
this_communication.Message := "MLM Field :" || CallingField || "\n" ||
"MLM Event :" || CallingEvent || "\n" ||
"Freq Val:" || freq_Val || "\n" ||
"Freq Summary: " || freq_Val.FrequencySummary;
this_communication.MessageType := "Informational"; */
;;
evoke: // No evoke statement
;;
logic:
conclude true;
;;
action:
// This MLM returns two parameters, of types communication_type and form_type respectively.
return this_communication, this_form;
;;
end: