maintenance:
title: Form_Berinert_Calc;;
mlmname: Form_Berinert_Calc;;
arden: version 2;;
version: 5.50;;
institution: St. Clair Hospital;;
author: Teresa Spicuzza ;;
specialist: Teresa Spicuzza ;;
date: 2012-05-21;;
validation: testing;;
library:
purpose: Caculate Berinert dose based on weight. Present dose rounded as:
500 - 600 units round to 500 units
601 - 999 units round to the nearest 50 units
1000 - 1100 units round to 1000 units
1101 - 1499 units - round to the nearest 50 units
1500 - 1600 units round to 1500 units
1601 - 1999 units round to the nearest 50 units
2000 - 2100 units round to 2000 units
2101 - 2499 units - round to nearest 50 units
2500 - 2600 units round to 2500 units
2601 - 3000 units - round to nearest 50 units
For patients < 25 kg, pop up a note that states:
"Dosing in children < 12y/o is not established." and allow for a type in a dose;
For patients > 150 kg, pop up a note that states:
"Clinical trials did not include obese patients > 150 kg. No specific dosing recommendations are available."
and allow for a type in a dose.
;;
explanation:
Dosing Weight in Kilograms * 20 = Dose
If Dosing Weight in Kilograms is null alert user to
Please enter a Weight before proceeding
Change history
03.18.2015 TMS New MLM to calculate and round Berinert C1 Esterase Inhibitor (Human) doses. CSR 24477
;;
keywords:
Berinert, weight; C1 Esterase Inhibitor (Human)
;;
knowledge:
type: data-driven;;
data:
/********************Make Changes To Spelling And Flags In This Section*********************/
/*************************************************************************************************/
// This MLM is passed three arguments, of types
// communication_type, form_type and client info object respectively.
(this_communication, // Communication object
this_form, // Form object
client_info_obj // Arden ClientInfo object
) := argument;
standard_libs := MLM {{{SINGLE-QUOTE}}}std_include_libs{{{SINGLE-QUOTE}}};
include standard_libs;
using "ObjectsPlusXA.SCM.Forms";
using namespace "ObjectsPlusXA.SunriseClinicalManager.Forms";
// Assigns fields passed in the Form object to the Field object
field_list:= this_form.fields;
CallingEvent := this_communication.CallingEvent;
CallingField := this_communication.CallingFieldName;
CR := 13 formatted with "%c";
LF := 10 formatted with "%c";
CRLF:= CR||LF;
adminInfo := first of
(field_list where field_list.DataItemName = "AdminInstructions");
OrderInfo := first of
(field_list where field_list.DataItemName = "PRX_NOTECOMMENT0");
comb_ht_wt_field := first of
(field_list where field_list.DataItemName = "CombinedMeasurements");
dose := first of
(field_list where field_list.DataItemName = "DosageLow");
dose_val := dose.value;
if exists comb_ht_wt_field then
comb_ht_wt_val := comb_ht_wt_field.value;
wt := comb_ht_wt_val.weight;
ht := comb_ht_wt_val.height;
wt_type := comb_ht_wt_val.weighttype;
bsa := comb_ht_wt_val.bsa;
bmi := comb_ht_wt_val.bmi;
endif;
If CallingEvent = "FormOpen" or (CallingEvent = "FieldChange" and callingfield = "CombinedMeasurements") then
if not exists wt or wt = 0 then
this_communication.Message :=
"Please Enter a Weight "
|| "before proceeding."
;
this_communication.MessageType := "Error";
else
wt_val := wt as number;
endif;
If (wt_val >= 25 and wt_val <= 150) then
//Dose
dose_calc := (wt as number) * 20;
If dose_calc >= 500 and dose_calc < 601 then
halffactor := 250; roundfactor := 500;
rndmessage := " (rounded to 500 mg) - ";
elseif
dose_calc >= 601 and dose_calc < 1000 then
halffactor := 25; roundfactor := 50;
rndmessage := " (rounded to nearest 50 mg) - ";
elseif
dose_calc >= 1000 and dose_calc < 1101 then
halffactor := 500; roundfactor := 1000;
rndmessage := " (rounded to 1000 mg) - ";
elseif
dose_calc >= 1101 and dose_calc < 1500 then
halffactor := 25; roundfactor := 50;
rndmessage := " (rounded to nearest 50 mg) - ";
elseif
dose_calc >= 1500 and dose_calc < 1601 then
halffactor := 750; roundfactor := 1500;
rndmessage := " (rounded to 1500 mg) - ";
elseif
dose_calc >= 1601 and dose_calc < 2000 then
halffactor := 25; roundfactor := 50;
rndmessage := " (rounded to nearest 50 mg) - ";
elseif
dose_calc >= 2000 and dose_calc < 2101 then
halffactor := 1000; roundfactor := 2000;
rndmessage := " (rounded to 2000 mg) - ";
elseif
dose_calc >= 2101 and dose_calc < 2500 then
halffactor := 25; roundfactor := 50;
rndmessage := " (rounded to nearest 50 mg) - ";
elseif
dose_calc >= 2500 and dose_calc < 2601 then
halffactor := 1250; roundfactor := 2500;
rndmessage := " (rounded to 2500 mg) - ";
elseif
dose_calc >= 2601 and dose_calc < 3000 then
halffactor := 25; roundfactor := 50;
rndmessage := " (rounded to nearest 50 mg) - ";
elseif
dose_calc >= 3000 then
halffactor := 1500; roundfactor := 3000;
rndmessage := " (rounded to 3000 mg) - ";
endif;
rnd_dose := int((dose_calc + halffactor)/roundfactor) * roundfactor;
if exists dose then
Dose.Value := rnd_dose ;
mltodraw := rnd_dose/50;
rawrate := ((rnd_dose /50) / 4);
rateofadmin := int((rawrate + 0.5)/1) * 1;
msg1 := "Dose calculated at 20 units/kg" ;
msg1b := "Final concentration after reconstitution is 50 units/ml. " ;
// msg1 := "Dose calculated at 20units/kg - Final concentration after reconstitution is 50units/ml. " ;
msg2 := "Administer " ;
msg2b := " units (";
msg3 := " ml) by slow IV injection at 4 ml/min. (" ;
msg4 := " minutes)";
dose.control_read_only := true;
admininfo.value := msg1 || rndmessage || msg1b || LF || LF || msg2 || rnd_dose || msg2b || mltodraw || msg3 || rateofadmin || msg4;
endif;
elseif
(wt as number) < 25 and (wt as number) > 0 then
this_communication.Message :=
"Dosing in children < 12y/o is not established. "
|| "Enter a dose if you wish to continue."
;
this_communication.MessageType := "Informational";
admininfo.value := " ";
Dose.Value := "";
dose.control_read_only := false;
elseif
(wt as number) > 150 then
this_communication.Message :=
"Clinical trials did not include obese patients > 150 kg. No specific dosing recommendations are available. "
|| "Enter a dose if you wish to continue."
;
this_communication.MessageType := "Informational";
admininfo.value := " ";
Dose.Value := "";
dose.control_read_only := false;
endif; // not exists wt
endif;
If CallingEvent = "FieldChange" and Callingfield = "DosageLow" then
wt_val := wt as number;
If (wt_val < 25 or wt_val > 150) and dose_val > 0 then
mltodraw := dose.value/50;
rawrate := ((dose.value /50) / 4);
rateofadmin := int((rawrate + 0.5)/1) * 1;
// msg1 := "Dose calculated at 20 units/kg" ;
msg1b := "Final concentration after reconstitution is 50 units/ml. " ;
msg2 := "Administer " ;
msg2b := " units (";
msg3 := " ml) by slow IV injection at 4 ml/min. (" ;
msg4 := " minutes)";
// dose.control_read_only := true;
admininfo.value := msg1b || LF || LF || msg2 || dose.value || msg2b || mltodraw || msg3 || rateofadmin || msg4;
endif;
endif;
;;
evoke:
;;
logic:
Conclude true;
;;
action:
// This MLM returns two parameters, of types
//communication_type and form_type respectively.
return this_communication, this_form;
;;
Urgency: 50;;
end: