maintenance:
|
|
|
|
title: Make read only fields available;;
|
|
mlmname: FORM_GENERIC_un_gray;;
|
|
arden: version 2;;
|
|
version: 4.50;;
|
|
institution: St Clair Hospital;;
|
|
author: Mary Sieger, Mary.Sieger@stclair.org, 412-942-1194;;
|
|
specialist: Eclipsys Corporation;;
|
|
date: 2006-10-26;;
|
|
validation: testing;;
|
|
|
|
library:
|
|
purpose: Based on a value provided in one field, make another field AVAILABLE.
|
|
;;
|
|
explanation: This generic MLM can be called from several order forms:
|
|
- LAB Chem Blood Gas
|
|
- (others?)
|
|
|
|
If a particular value is placed in a certain field of a certain form, specified by
|
|
the configuration list below, then another field, also in the list, will be made to
|
|
be available (i.e. un-grayed).
|
|
|
|
Trigger on formopen or fieldchange.
|
|
|
|
Rules:
|
|
Use lists of
|
|
forms,
|
|
fields to test on the form,
|
|
values to test for,
|
|
field to make available (if the value in the other field is present)
|
|
|
|
|
|
change history
|
|
|
|
2.11.2007 DJW added a new form, LAB ChemBloodGas_Tmp.
|
|
5.29.2015 MJP CSR#33459 added new fields for High Flow
|
|
|
|
;;
|
|
keywords: Called MLMs, Form fields, generic, field test, read-only
|
|
;;
|
|
knowledge:
|
|
type: data-driven;;
|
|
data:
|
|
|
|
/***********************Make Changes To Spelling And Flags In This Section************************/
|
|
|
|
//NOTE: THE RELATIVE ORDER OF ITEMS MUST BE MAINTAINED WITHIN LISTS!!!
|
|
//MUST HAVE THE FOLLOWING ORDER FOR EACH ELEMENT ITEM:
|
|
//"FORM_NAME|FIELD_NAME_TO_TEST|VALUEs_TO_TEST_FOR|FIELD_TO_MAKE_NOT_READ_ONLY"
|
|
|
|
form_map_list :=
|
|
("LAB Chem Blood Gas|LAB_RC_BGCMT_RespAerosolMode|(any_value)|LAB_RC_BGCMT_LV_RespAerosolConc"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_RespMode_BIPAP_CPAP"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespIPAPcmH2O"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespEPAPcmH2O"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPO2"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPLPM"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_VT"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_O2ConcFIO2"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PEEP"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PressureSupport"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_Rate"
|
|
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_HiFloNCLPM|(any_value)|LAB_RC_BGCMT_LV_HiFloNC%"
|
|
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_RespAerosolMode|(any_value)|LAB_RC_BGCMT_LV_RespAerosolConc"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_RespMode_BIPAP_CPAP"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespIPAPcmH2O"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespEPAPcmH2O"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPO2"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPLPM"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_VT"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_O2ConcFIO2"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PEEP"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PressureSupport"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_Rate"
|
|
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_HiFloNCLPM|(any_value)|LAB_RC_BGCMT_LV_HiFloNC%"
|
|
|
|
|
|
|
|
,"YOUR_FORM_NAME_HERE|YOUR_TEST_FIELD_HERE|VALID_VAL1,VALID_VAL2|UN_GRAY_FIELD_HERE"
|
|
);
|
|
|
|
/**************************************************************************************JAB********/
|
|
|
|
// This MLM is passed three arguments, of types
|
|
// communication_type, form_type and client info object respectively.
|
|
|
|
(this_communication, // Communication object
|
|
this_form, // Form object
|
|
client_info_obj //Arden ClientInfo object
|
|
) := argument;
|
|
|
|
//Initialize MLM pointers:
|
|
str_parse := mlm {{{SINGLE-QUOTE}}}UTIL_STRING_PARSE{{{SINGLE-QUOTE}}};
|
|
chk_overdue_time := MLM {{{SINGLE-QUOTE}}}overdue_req_time{{{SINGLE-QUOTE}}};
|
|
|
|
// Initialize error message
|
|
error_message:="";
|
|
|
|
|
|
// Assigns fields passed in the Form object to the Field object
|
|
field_list:= this_form.fields;
|
|
|
|
CallingForm := this_form.name;
|
|
CallingEvent := this_communication.CallingEvent;
|
|
CallingField := this_communication.CallingFieldName;
|
|
|
|
if called_by_editor then
|
|
CallingForm := "LAB Chem Blood Gas";
|
|
CallingEvent := "FieldChange";
|
|
CallingField := "LAB_RC_BGCMT_RespAerosolMode";
|
|
endif;
|
|
|
|
for i in 1 seqto count form_map_list do
|
|
// initialize vars:
|
|
visible_field := null;
|
|
trigger_field := null;
|
|
|
|
// parse the form mapper:
|
|
form_element_list := call str_parse with form_map_list[i], "|";
|
|
test_form_name := form_element_list[1]; //Lookup form name from map list
|
|
|
|
// Test for proper form
|
|
if CallingForm = test_form_name then
|
|
|
|
test_visible_field := form_element_list[4]; //Lookup visible field from map list
|
|
|
|
visible_field := first of
|
|
(field_list where field_list.DataItemName = test_visible_field);
|
|
|
|
// Set open form defaults
|
|
if exists visible_field then
|
|
|
|
test_field := form_element_list[2]; //Lookup test field from map list
|
|
trigger_field := first of
|
|
(field_list where field_list.DataItemName = test_field);
|
|
|
|
//check for {{{SINGLE-QUOTE}}}additional info{{{SINGLE-QUOTE}}} fields
|
|
if visible_field.dataitemname = "LAB_SREQ_VO_DI_MicroDescript" then
|
|
Right_box := last of (field_list
|
|
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Right" );
|
|
Superficial_box := last of (field_list
|
|
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Superficial" );
|
|
Left_box := last of (field_list
|
|
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Left" );
|
|
Deep_box := last of (field_list
|
|
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Deep" );
|
|
endif;
|
|
// Test for proper field
|
|
if exists trigger_field then
|
|
//Lookup list of valid values for the test field
|
|
test_val_list := call str_parse with form_element_list[3], ",";
|
|
|
|
//Check for time field
|
|
|
|
if trigger_field.dataitemname = "RequestedTime"
|
|
and "overdue" is in test_val_list then
|
|
if exists trigger_field.value.reqtimevalue then
|
|
time_type := "scheduled";
|
|
time_val := trigger_field.value.reqtimevalue;
|
|
else
|
|
time_type := "coded";
|
|
time_val := trigger_field.value.reqtimecode;
|
|
endif;
|
|
// check for overdue time
|
|
time_is_overdue := call chk_overdue_time
|
|
with time_val, time_type;
|
|
endif;
|
|
|
|
if ((trigger_field.value as string) is in test_val_list)
|
|
or ("(any_value)" is in test_val_list and trigger_field.value is not null)
|
|
or time_is_overdue then
|
|
|
|
// Make the field UN-GRAYED (but NOT Mandatory!)
|
|
visible_field.control_read_only := false;
|
|
|
|
// make {{{SINGLE-QUOTE}}}additional info{{{SINGLE-QUOTE}}} settings writable
|
|
if visible_field.dataitemname = "LAB_SREQ_VO_DI_MicroDescript" then
|
|
Right_box.control_read_only := False;
|
|
Superficial_box.control_read_only := False;
|
|
Left_box.control_read_only := False;
|
|
Deep_box.control_read_only := False;
|
|
else
|
|
Right_box.control_read_only := true;
|
|
Superficial_box.control_read_only := True;
|
|
Left_box.control_read_only := True;
|
|
Deep_box.control_read_only := True;
|
|
// Right_box.value := null;
|
|
// Superficial_box.value := null;
|
|
// Left_box.value := null;
|
|
// Deep_box.value := null;
|
|
endif;
|
|
|
|
else
|
|
visible_field.control_read_only := true;
|
|
visible_field.value := "";
|
|
if visible_field.dataitemname = "LAB_SREQ_VO_DI_MicroDescript" then
|
|
Right_box.control_read_only := true;
|
|
Superficial_box.control_read_only := True;
|
|
Left_box.control_read_only := True;
|
|
Deep_box.control_read_only := True;
|
|
Right_box.value := "";
|
|
Superficial_box.value := "";
|
|
Left_box.value := "";
|
|
Deep_box.value := "";
|
|
endif;
|
|
|
|
endif; // (trigger_field.value as string) is in test_val_list
|
|
/*
|
|
// FOR DEBUGGING PURPOSES: display a message to the user
|
|
this_communication.Message :=
|
|
"callingform = "|| callingform
|
|
|| "\nCallingEvent = " || CallingEvent
|
|
|| "\ntest_form_name = " || test_form_name
|
|
|| "\ntest_field = " || test_field
|
|
|| "\ntest_visible_field = " || test_visible_field
|
|
|| "\ntrigger_field = " || trigger_field.dataitemname
|
|
|| "\nvisible_field = " || visible_field.dataitemname
|
|
|| "\ntrigger_field.value = " || trigger_field.value
|
|
|| "\ntest_val_list = " || test_val_list
|
|
|| "\nvisible_field = " || visible_field
|
|
|| "\ntime_is_overdue = " ||time_is_overdue;
|
|
this_communication.MessageType := "Informational";
|
|
*/
|
|
endif; // exists trigger_field
|
|
|
|
endif; // exists visible_field
|
|
|
|
endif; // CallingForm = test_form_name
|
|
|
|
enddo; // for i in 1 seqto count form_map_list
|
|
;;
|
|
evoke: // No evoke statement
|
|
;;
|
|
logic:
|
|
conclude true;
|
|
;;
|
|
action:
|
|
// This MLM returns two parameters, of types
|
|
//communication_type and form_type respectively.
|
|
return this_communication, this_form;
|
|
;;
|
|
end:
|