maintenance:
title: Make read only fields available;;
mlmname: FORM_GENERIC_un_gray;;
arden: version 2;;
version: 4.50;;
institution: St Clair Hospital;;
author: Mary Sieger, Mary.Sieger@stclair.org, 412-942-1194;;
specialist: Eclipsys Corporation;;
date: 2006-10-26;;
validation: testing;;
library:
purpose: Based on a value provided in one field, make another field AVAILABLE.
;;
explanation: This generic MLM can be called from several order forms:
- LAB Chem Blood Gas
- (others?)
If a particular value is placed in a certain field of a certain form, specified by
the configuration list below, then another field, also in the list, will be made to
be available (i.e. un-grayed).
Trigger on formopen or fieldchange.
Rules:
Use lists of
forms,
fields to test on the form,
values to test for,
field to make available (if the value in the other field is present)
change history
2.11.2007 DJW added a new form, LAB ChemBloodGas_Tmp.
5.29.2015 MJP CSR#33459 added new fields for High Flow
;;
keywords: Called MLMs, Form fields, generic, field test, read-only
;;
knowledge:
type: data-driven;;
data:
/***********************Make Changes To Spelling And Flags In This Section************************/
//NOTE: THE RELATIVE ORDER OF ITEMS MUST BE MAINTAINED WITHIN LISTS!!!
//MUST HAVE THE FOLLOWING ORDER FOR EACH ELEMENT ITEM:
//"FORM_NAME|FIELD_NAME_TO_TEST|VALUEs_TO_TEST_FOR|FIELD_TO_MAKE_NOT_READ_ONLY"
form_map_list :=
("LAB Chem Blood Gas|LAB_RC_BGCMT_RespAerosolMode|(any_value)|LAB_RC_BGCMT_LV_RespAerosolConc"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_RespMode_BIPAP_CPAP"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespIPAPcmH2O"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespEPAPcmH2O"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPO2"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPLPM"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_VT"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_O2ConcFIO2"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PEEP"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PressureSupport"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_Rate"
,"LAB Chem Blood Gas|LAB_RC_BGCMT_LV_HiFloNCLPM|(any_value)|LAB_RC_BGCMT_LV_HiFloNC%"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_RespAerosolMode|(any_value)|LAB_RC_BGCMT_LV_RespAerosolConc"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_RespMode_BIPAP_CPAP"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespIPAPcmH2O"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespEPAPcmH2O"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPO2"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_BIPAP_CPAP|(any_value)|LAB_RC_BGCMT_LV_RespBIPAPCPAPLPM"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_VT"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_O2ConcFIO2"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PEEP"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_PressureSupport"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_RespVentMode|(any_value)|LAB_RC_BGCMT_LV_RespVent_Rate"
,"LAB ChemBloodGas_Tmp|LAB_RC_BGCMT_LV_HiFloNCLPM|(any_value)|LAB_RC_BGCMT_LV_HiFloNC%"
,"YOUR_FORM_NAME_HERE|YOUR_TEST_FIELD_HERE|VALID_VAL1,VALID_VAL2|UN_GRAY_FIELD_HERE"
);
/**************************************************************************************JAB********/
// This MLM is passed three arguments, of types
// communication_type, form_type and client info object respectively.
(this_communication, // Communication object
this_form, // Form object
client_info_obj //Arden ClientInfo object
) := argument;
//Initialize MLM pointers:
str_parse := mlm {{{SINGLE-QUOTE}}}UTIL_STRING_PARSE{{{SINGLE-QUOTE}}};
chk_overdue_time := MLM {{{SINGLE-QUOTE}}}overdue_req_time{{{SINGLE-QUOTE}}};
// Initialize error message
error_message:="";
// Assigns fields passed in the Form object to the Field object
field_list:= this_form.fields;
CallingForm := this_form.name;
CallingEvent := this_communication.CallingEvent;
CallingField := this_communication.CallingFieldName;
if called_by_editor then
CallingForm := "LAB Chem Blood Gas";
CallingEvent := "FieldChange";
CallingField := "LAB_RC_BGCMT_RespAerosolMode";
endif;
for i in 1 seqto count form_map_list do
// initialize vars:
visible_field := null;
trigger_field := null;
// parse the form mapper:
form_element_list := call str_parse with form_map_list[i], "|";
test_form_name := form_element_list[1]; //Lookup form name from map list
// Test for proper form
if CallingForm = test_form_name then
test_visible_field := form_element_list[4]; //Lookup visible field from map list
visible_field := first of
(field_list where field_list.DataItemName = test_visible_field);
// Set open form defaults
if exists visible_field then
test_field := form_element_list[2]; //Lookup test field from map list
trigger_field := first of
(field_list where field_list.DataItemName = test_field);
//check for {{{SINGLE-QUOTE}}}additional info{{{SINGLE-QUOTE}}} fields
if visible_field.dataitemname = "LAB_SREQ_VO_DI_MicroDescript" then
Right_box := last of (field_list
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Right" );
Superficial_box := last of (field_list
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Superficial" );
Left_box := last of (field_list
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Left" );
Deep_box := last of (field_list
where field_list.DataItemName = "LAB_SREQ_LO_CB_Micro_Deep" );
endif;
// Test for proper field
if exists trigger_field then
//Lookup list of valid values for the test field
test_val_list := call str_parse with form_element_list[3], ",";
//Check for time field
if trigger_field.dataitemname = "RequestedTime"
and "overdue" is in test_val_list then
if exists trigger_field.value.reqtimevalue then
time_type := "scheduled";
time_val := trigger_field.value.reqtimevalue;
else
time_type := "coded";
time_val := trigger_field.value.reqtimecode;
endif;
// check for overdue time
time_is_overdue := call chk_overdue_time
with time_val, time_type;
endif;
if ((trigger_field.value as string) is in test_val_list)
or ("(any_value)" is in test_val_list and trigger_field.value is not null)
or time_is_overdue then
// Make the field UN-GRAYED (but NOT Mandatory!)
visible_field.control_read_only := false;
// make {{{SINGLE-QUOTE}}}additional info{{{SINGLE-QUOTE}}} settings writable
if visible_field.dataitemname = "LAB_SREQ_VO_DI_MicroDescript" then
Right_box.control_read_only := False;
Superficial_box.control_read_only := False;
Left_box.control_read_only := False;
Deep_box.control_read_only := False;
else
Right_box.control_read_only := true;
Superficial_box.control_read_only := True;
Left_box.control_read_only := True;
Deep_box.control_read_only := True;
// Right_box.value := null;
// Superficial_box.value := null;
// Left_box.value := null;
// Deep_box.value := null;
endif;
else
visible_field.control_read_only := true;
visible_field.value := "";
if visible_field.dataitemname = "LAB_SREQ_VO_DI_MicroDescript" then
Right_box.control_read_only := true;
Superficial_box.control_read_only := True;
Left_box.control_read_only := True;
Deep_box.control_read_only := True;
Right_box.value := "";
Superficial_box.value := "";
Left_box.value := "";
Deep_box.value := "";
endif;
endif; // (trigger_field.value as string) is in test_val_list
/*
// FOR DEBUGGING PURPOSES: display a message to the user
this_communication.Message :=
"callingform = "|| callingform
|| "\nCallingEvent = " || CallingEvent
|| "\ntest_form_name = " || test_form_name
|| "\ntest_field = " || test_field
|| "\ntest_visible_field = " || test_visible_field
|| "\ntrigger_field = " || trigger_field.dataitemname
|| "\nvisible_field = " || visible_field.dataitemname
|| "\ntrigger_field.value = " || trigger_field.value
|| "\ntest_val_list = " || test_val_list
|| "\nvisible_field = " || visible_field
|| "\ntime_is_overdue = " ||time_is_overdue;
this_communication.MessageType := "Informational";
*/
endif; // exists trigger_field
endif; // exists visible_field
endif; // CallingForm = test_form_name
enddo; // for i in 1 seqto count form_map_list
;;
evoke: // No evoke statement
;;
logic:
conclude true;
;;
action:
// This MLM returns two parameters, of types
//communication_type and form_type respectively.
return this_communication, this_form;
;;
end: